1.
A healthcare customer is not satisfied with the utilization of their heterogeneous storage devices. Which ol the tollowing solutions should the System x technical representative recommend to better provision their storage on demand?
2.
A Customer has a proprietary server deployment solution that uses a combination of disk imaging and application pushing technology. They need to get a working Windows 2003 image lor their new servers as soon as possible for deployment with their provisioning system. Which of the following methods can achieve this?
3.
A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. The customer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy?
4.
How many BladeCenter HT chassis will fit in a standard 19" 42U rack?
5.
A banking cuslomer has the following requirement lor an IBM BladeCenter solution wilh high speed libre channel:
- (our 4-sockel Microsott SQL servers wilh two hoi swap SAS drives
- two physical Microsoft Active Directory Servers
- twenty-two physical Citrix servers
- three physical Web servers
- one physical vCenter server
- eight vSphere hosts
Which contiguration minimally satisties these requirements?
6.
A University customer has a BladeCenler H fully populated with LS21 Blades, a single AMM, and four power modules. The BladeCenter has been running flawlessly for three months. One day an administrator discovers that they cannot view video on blades 9-12 either locally or remotely even though they still appear to be running. The video works on all of the other blades. Which of the following is the cause of the video problem?
7.
An insurance customer installs two BladeCenter chassis in a rack with glass doors. After a short time, the blowers in both BladeCenters increase to full speed, and then one fails. Apart from replacing the broken blowers, which additional action is required for a long term fix?
8.
A distribution customer has a BladeCenter chassis with a single AMM that is defective. The customer has backed up the AMM configuration using the Web interlace and places a new AMM in the chassis. Upon restart, the new AMM still has the factory default settings. Why didn't the previous AMM configuration automatically load in the new AMM?
9.
A banking customer has two Ethernet Switch Modules installed in an IBM BCE chassis. The modules were configured identically. The Ethernet module in bay 1 was accidentally reset to factory defaults. Which solution returns the module to the customer-specific configuration?
10.
An IBM System x Technical Expert has a prospective customer who is very excited about X5 and they are working on configurations. During the process the customer has changed the design numerous times and has significantly increased the scope. They recently selected a Business Partner who has been involved in the last few design changes. What steps should be taken to make sure the customer is satisfied with the solution?