A customer Is using an HP ProLiant BL460c Gen9 Server with HP FlexFabric 20Gb 2-port 650FLB and an HP c7000 BladeSystem Enclosure with Virtual Connect FlexFabric 20/40 F8 interconnect modules in bays 1 and 2. The integrator is configuring networks and server profiles in HP OneView and needs to attach a server blade to a VLAN 51. The integrator will tag proper ports on appropriate switches to take VLAN 51 to the enclosure. Which configuration will bring high-availability and fault tolerance against a server port and uplink port failures for VLAN 51?
A customer is implementing a new rack solution in their datacenter. The racks will be supporting a variety of HP ProLiant Gen9 servers in each rack, and the racks will be sharing a common hot aisle due to space limitations. The customer is concerned about the amount of heat that will be generated. What should the integrator recommend to the customer for the installation of the racks?
A customer has an HP FlexFabric 650FLB on an HP BL460c Gen9 running VMware ESXi 6.0. The integrator needs to upgrade the driver for this adapter to the latest version released by HP. To avoid a manual download, the integrator plans to use VMware Update Manager (VUM) to download the driver directly. Where should the integrator point VMware Update Manager?
A customer with HP ProLiant DL360 Gen9 servers needs to combine Fibre Channel over Ethernet (FCoE) with their LAN traffic over a single 10GbE connection. Which FlexFabric adapter meets the customer's needs?
A server integrator determines that power supply units (PSUs) are failing during the installation of new IT equipment at a specific customer site. Based on the HP 6-Step Troubleshooting Methodology, what should the integrator do?
A customer is implementing HP Location Discovery Services to manage and monitor power consumption in the data center. The customer has purchased HP iPDU units for some cabinets. Which guideline must the integrator follow when installing the new PDUs into the existing racks?
A customers design includes a 40GB uplink to their data center network Which ports on the HP Virtual Connect FlexFabric-20/40 F8 module should the integrator use to connect the uplinks?
An integrator needs to install two new rows of server racks in a data center. What is the minimum space required from the back of a rack to the back of the next closest rack.
A company needs servers to implement Virtual Extensible LAN (VXLAN), an overlay networking technology. How do HP FlexFabric 556 series adapters enhance functionality for these servers?