A customer has two HPE Nimble arrays that are replication partners. The customer suffers a complete outage on the source array. What does the administrator need to do to make the most recent snapshot available?
A customer requests a proposal for two HPE 3PAR arrays using asynchronous periodic replication. The customer has two data centers, and the current bandwidth available for replication between the data centers is 200 Mb/s. The customer is replicating 30TB, and the change rate is 3% in 24 hours. The customer wants to achieve an RPO of 10 minutes. Which statement about bandwidth and replication is true for the customer requirements?
You are discussing a HPE 3PAR Remote Copy solution with your customer. The customer has had a bad experience in their current non-HPE replication solution. Currently the source and target volume properties on the array must be identical on both sides and cannot be changed without re-creating the volumes. What should you explain to the customer?
You receive an error when attempting to utilize SAF Analyze to upload customer data that you have collected to develop reports for a new proposal. What must you do first tobegin the process?
A customer has two HPE 3PAR arrays which are using Remote Copy and AO. The customer notices a large portion of the data is residing in the NL tier of the secondary array, while all tiers are utilized evenly on the primary array. Which statement about the secondary array behavior is true?
An HPE Nimble customer needs to consolidate storage and scale performance. They are looking to purchase additional hardware to meet these requirements. What is the best solution to offer this customer?
A customer has a Tier 1 application that has high bandwidth and is sensitive to latency. The customer needs a solution to support this application. The solution must support replication between two sites over dark fiber links and support an RPO of zero. Which solution meets the customer requirements?
A customer is interested in using HPE InfoSight Cross-stack Analytics for VMware. Where does the customer need to make the appropriate configuration changes to makes this active?
A customer has two HPE Nimble arrays that are replication partners. The replication schedule is set to every hour. After replication completed at 1:00pm, the array at the primary site suffers a power failure. Applications were failed over successfully by the administrators, and production continued on the secondary site array as designed. At 3:00pm, the power was restored to the primary site array. What does the administrator need to do first to restore services in the primary site?