1.
MDS3 _ 9509# install all system bootflash:m9500-sf1 ek9-mz.1.3.4.bin kickstart bootflash:m9500-sfek9- kickstart-mz.1.3.4.bin Verifying image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################]
100% -- SUCCESS Verifying image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################]
100% -- SUCCESS Extracting "sic"version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin
[####################] 100% -- SUCCESS Extracting "ips" version from image bootflash:/m9500-
sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting "system" version from
image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting
"kickstart"version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100%
-- SUCCESS Extracting "loader" version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin
[####################] 100% -- SUCCESS Compatibility check is done: Module bootable impact install-type
reason
--------- --------- ---------- ------- ----- ---------
2 yes non-disruptive rolling
3 yes disruptive rolling Hitless upgrade is not supported 5 yes non-disruptive reset 6 yes non-disruptive reset
Images will be upgraded according to following table: Module Image Running-Version Net-Version Upg-
Required
--------- ------- ---------- ----------- ------ ----------
2 slc 1.3(4b) 1.3(4) yes
2 bios v1.1.0(10/24.03) v10.8(08/07/03) no
3 slc 1.3(4b) 1.3(4) yes
3 bios v1.1.0(10/24.03) v10.8(08/07/03) no
5 system 1.3(4b) 1.3(4) yes
5 kickstart 1.3(4b) 1.3(4) yes
5 bios v1.1.0(10/24.03) v10.8(08/07/03) no
5 loader 1.2(2) 1.2(2) no
6 system 1.3(4b) 1.3(4) yes
6 kickstart 1.3(4b) 1.3(4) yes
6 bios v1.1.0(10/24.03) v10.8(08/07/03) no
6 loader 1.2(2) 1.2(2) no
Do you want to continue with the installation (y/n)? [n] What is the reason the upgrade would not be hit-less for the entire switch, above?
2.
In a scenario with three lSLs between two switches, a single host in VSAN 5 on switch A, and a single storage device on switch B in the same VSAN. What would be the effect on the lSLs if Flow based load balancing option was enabled in VSAN 5?
3.
What is the User-specified VSAN Ids range?
4.
What can be configured on a FCIP Profile?
5.
A Brocade 12000 in its native corePID mode (1) is connected to VSAN 1009 on an MDS. What is the correct output of the "show vsan 1009" command?
6.
What TCP feature reduces the chances of an oversized IP packets from being fragmented?
7.
In Raid 0+1 the loss of a single drive:
8.
What zoning option can be used in interop mode 2 and 3?
9.
You have a legacy JBOD that uses copper DB-9 connecters. You want to connect your JBOD to a Fiber only
Fiber Channel switch. You want to convert the DB-9 connection to multi mode Fiber Optics. What device would you use?
10.
FCIP Write Acceleration most effectively addresses which disaster recovery challenge?