You are connecting 2 existing independent fabrics in VSAN 2. Fabric 1 has domains 100 and 101. Fabric 2 has domains 100 and 101. All of the switches have the below interface configuration for all ports used for ISLs.
Fabric 1 has an active zoneset in VSAN 2 with one zone containing hosts Alpha, Charlie and Delta and storage devices EMC1 and Hitachi 1. Fabric 2 has no active zoneset. Why did the fabrics fail to merge? MDS9506-B1#
interface fcX/Y fcdomain rcf-reject vsan 2 switchport mode E
Two switches are merging together. During principal switch selection, Switch A sends a frame indicating it has an empty domain ID list. Switch B sends a frame indicating that there are previously allocated domain IDs.
Switch A has a lower priority value and a lower WWN. What should occur next?
A customer has existing production fabric with Brocade and McData FC switches intermixed. When adding an
MOS 9000 switch, what MDS interop mode would be required?
(Topology: McData6400 - (ISL) - Brocade12000 - (ISL) -- MDS)